Hanshin S-Class Autoclave
HSAXXX
This S-Class large steam steriliser is equipped with a rectangular chamber, resulting in a more effective use of the volume of the chamber. The ability to process more kits concurrently saves time and allows improved clinic efficiency. In addition, the increased usable chamber size allows the processing of larger kits.
Overall Dimensions: W615 x D757 x H505 mmChamber Dimensions: W302 x D450 x H302 mm
1. Unique small steam generator This steriliser is equipped with the new type external steam generator which can vaporise water instantly, and the saturated vapor is injected into the chamber as a sterilising media, therefore the chamber is less contaminated than the internal steam generating type and the usable chamber space is widened because there is no heater assembly in the chamber. 2. Use of clean steam every cycleThe used water after completing a sterilising cycle is collected in the collecting container designed separately with the reservoir, therefore the saturated steam generated by a clean water always can be supplied to perform every sterilising cycle. 3. Safe and durable unwelded chamberBy adopting a integral chamber unwelded, the durability is excellent and a trouble such as leaking of pressurised vapor and vacuum during progressing a cycle is not occurred accidently. 4. Various cycle programs of the optimum condition5 kinds of the basic cycle program composed of the optimum sterilisation parameters are installed in this steriliser and the operator can select a proper cycle program among them conveniently for sterilising, moreover user can change the set values of the basic cycle programs as user's please if necessary for applying to a special sterilisation condition or materials. 5. Safe and convenient self-diagnosis functionIf an error has occurred during operating the steriliser, it is detected and the error code is displayed on the LED display accompanying an audible alarm, and the cycle in progress is aborted automatically for safety by the built-in self-diagnosis program.6. Convenient monitoring of a cycle processingThe operator is able to check a cycle progressing conveniently on the LED display because the state of steriliser operation is displayed digitally in real time on it. 7.Cycle Execution Data Storing and Ubiquitous FunctionThe cycle performance records executed at least for 11 years are stored in the control unit in order. The user can automatically search the results of sterilisation cycle performed previously by input the date performed cycle or the cycle count number and prints out the result record by the built-in panel printer. (optional specification) The user can download or backup those data in the USB memory and monitor the operation of steriliser on the external PC by connecting the USB or LAN cable to the built-in communication ports. Moreover the communication program including an ubiquitous function provided allows user to manage the operation of plural(maximum 15 sets) sterilisers at once. (optional specification)
* 2-year warranty.
ModelHS-3041SDOverall DimensionW615 x D757 x H505 ???ChamberW302 x D450 x H302 ???, Vol: 40.5???, Material: STS 316LMax. Working pressure: 2.4 bar / Min. Working Pressure: -1.00 bar
Max. Working Temperature: 138.0??? / Test Pressure : 5.13 barReservoir/Collection ContainerCapacity; 7.5??? / 7.5??? (Full water level)TrayW288 x D410 x H18 ???, 4 eaOperating Temperature121.0??? ~ 135.0??? (Display Resolution; 0.1???)SterilantSaturated vaporAir Removal MethodPositive Pressure PulseAir Removal DeviceVacuum Pump (Diaphragm type)ControlsMicroprocessorDisplayDigital LED DisplayPanel Printer
(Optional)Exterior type, Direct thermal printing, Printing Paper Roll: W58 x ??60 mmPower SourceAC 230V, 50/60HzPower Consumption3,300 WNet Weight78 kgEnvironment Conditions
(IEC 61010-1)* Altitudes up to 2,000 m
* Temperature range of +5??? to +40???.
* Maximum Relative Humidity 80% for temperatures up to 31??? decreasing linearly to 50% relative humidity at 40???.
* Mains supply voltage fluctuations up to ??10% of the nominal.
* Installation Category (Overvoltage Category): ???, Pollution Degree : 2.
PLEASE NOTE: THIS UNIT REQUIRES A 15AMP POWER SUPPLY, PLEASE PHONE US TO DISCUSS AS ADDITIONAL CHARGES MAY APPLY
HSA212
Door Handle For HS-2321BL - HS-3041SD and HS-2522SD
Hanshin S-Class Autoclave - Door Handle For HS-2321BL - HS-3041SD and HS-2522SD
This S-Class large steam steriliser is equipped with a rectangular chamber, resulting in a more effective use of the volume of the chamber. The ability to process more kits concurrently saves time and allows improved clinic efficiency. In addition, the increased usable chamber size allows the processing of larger kits.
Overall Dimensions: W615 x D757 x H505 mmChamber Dimensions: W302 x D450 x H302 mm
1. Unique small steam generator This steriliser is equipped with the new type external steam generator which can vaporise water instantly, and the saturated vapor is injected into the chamber as a sterilising media, therefore the chamber is less contaminated than the internal steam generating type and the usable chamber space is widened because there is no heater assembly in the chamber. 2. Use of clean steam every cycleThe used water after completing a sterilising cycle is collected in the collecting container designed separately with the reservoir, therefore the saturated steam generated by a clean water always can be supplied to perform every sterilising cycle. 3. Safe and durable unwelded chamberBy adopting a integral chamber unwelded, the durability is excellent and a trouble such as leaking of pressurised vapor and vacuum during progressing a cycle is not occurred accidently. 4. Various cycle programs of the optimum condition5 kinds of the basic cycle program composed of the optimum sterilisation parameters are installed in this steriliser and the operator can select a proper cycle program among them conveniently for sterilising, moreover user can change the set values of the basic cycle programs as user's please if necessary for applying to a special sterilisation condition or materials. 5. Safe and convenient self-diagnosis functionIf an error has occurred during operating the steriliser, it is detected and the error code is displayed on the LED display accompanying an audible alarm, and the cycle in progress is aborted automatically for safety by the built-in self-diagnosis program.6. Convenient monitoring of a cycle processingThe operator is able to check a cycle progressing conveniently on the LED display because the state of steriliser operation is displayed digitally in real time on it. 7.Cycle Execution Data Storing and Ubiquitous FunctionThe cycle performance records executed at least for 11 years are stored in the control unit in order. The user can automatically search the results of sterilisation cycle performed previously by input the date performed cycle or the cycle count number and prints out the result record by the built-in panel printer. (optional specification) The user can download or backup those data in the USB memory and monitor the operation of steriliser on the external PC by connecting the USB or LAN cable to the built-in communication ports. Moreover the communication program including an ubiquitous function provided allows user to manage the operation of plural(maximum 15 sets) sterilisers at once. (optional specification)
* 2-year warranty.
ModelHS-3041SDOverall DimensionW615 x D757 x H505 ???ChamberW302 x D450 x H302 ???, Vol: 40.5???, Material: STS 316LMax. Working pressure: 2.4 bar / Min. Working Pressure: -1.00 bar
Max. Working Temperature: 138.0??? / Test Pressure : 5.13 barReservoir/Collection ContainerCapacity; 7.5??? / 7.5??? (Full water level)TrayW288 x D410 x H18 ???, 4 eaOperating Temperature121.0??? ~ 135.0??? (Display Resolution; 0.1???)SterilantSaturated vaporAir Removal MethodPositive Pressure PulseAir Removal DeviceVacuum Pump (Diaphragm type)ControlsMicroprocessorDisplayDigital LED DisplayPanel Printer
(Optional)Exterior type, Direct thermal printing, Printing Paper Roll: W58 x ??60 mmPower SourceAC 230V, 50/60HzPower Consumption3,300 WNet Weight78 kgEnvironment Conditions
(IEC 61010-1)* Altitudes up to 2,000 m
* Temperature range of +5??? to +40???.
* Maximum Relative Humidity 80% for temperatures up to 31??? decreasing linearly to 50% relative humidity at 40???.
* Mains supply voltage fluctuations up to ??10% of the nominal.
* Installation Category (Overvoltage Category): ???, Pollution Degree : 2.
PLEASE NOTE: THIS UNIT REQUIRES A 15AMP POWER SUPPLY, PLEASE PHONE US TO DISCUSS AS ADDITIONAL CHARGES MAY APPLY
Product #:
HSA212
HSA200
Air Filter
Hanshin S-Class Autoclave - Air Filter
This S-Class large steam steriliser is equipped with a rectangular chamber, resulting in a more effective use of the volume of the chamber. The ability to process more kits concurrently saves time and allows improved clinic efficiency. In addition, the increased usable chamber size allows the processing of larger kits.
Overall Dimensions: W615 x D757 x H505 mmChamber Dimensions: W302 x D450 x H302 mm
1. Unique small steam generator This steriliser is equipped with the new type external steam generator which can vaporise water instantly, and the saturated vapor is injected into the chamber as a sterilising media, therefore the chamber is less contaminated than the internal steam generating type and the usable chamber space is widened because there is no heater assembly in the chamber. 2. Use of clean steam every cycleThe used water after completing a sterilising cycle is collected in the collecting container designed separately with the reservoir, therefore the saturated steam generated by a clean water always can be supplied to perform every sterilising cycle. 3. Safe and durable unwelded chamberBy adopting a integral chamber unwelded, the durability is excellent and a trouble such as leaking of pressurised vapor and vacuum during progressing a cycle is not occurred accidently. 4. Various cycle programs of the optimum condition5 kinds of the basic cycle program composed of the optimum sterilisation parameters are installed in this steriliser and the operator can select a proper cycle program among them conveniently for sterilising, moreover user can change the set values of the basic cycle programs as user's please if necessary for applying to a special sterilisation condition or materials. 5. Safe and convenient self-diagnosis functionIf an error has occurred during operating the steriliser, it is detected and the error code is displayed on the LED display accompanying an audible alarm, and the cycle in progress is aborted automatically for safety by the built-in self-diagnosis program.6. Convenient monitoring of a cycle processingThe operator is able to check a cycle progressing conveniently on the LED display because the state of steriliser operation is displayed digitally in real time on it. 7.Cycle Execution Data Storing and Ubiquitous FunctionThe cycle performance records executed at least for 11 years are stored in the control unit in order. The user can automatically search the results of sterilisation cycle performed previously by input the date performed cycle or the cycle count number and prints out the result record by the built-in panel printer. (optional specification) The user can download or backup those data in the USB memory and monitor the operation of steriliser on the external PC by connecting the USB or LAN cable to the built-in communication ports. Moreover the communication program including an ubiquitous function provided allows user to manage the operation of plural(maximum 15 sets) sterilisers at once. (optional specification)
* 2-year warranty.
ModelHS-3041SDOverall DimensionW615 x D757 x H505 ???ChamberW302 x D450 x H302 ???, Vol: 40.5???, Material: STS 316LMax. Working pressure: 2.4 bar / Min. Working Pressure: -1.00 bar
Max. Working Temperature: 138.0??? / Test Pressure : 5.13 barReservoir/Collection ContainerCapacity; 7.5??? / 7.5??? (Full water level)TrayW288 x D410 x H18 ???, 4 eaOperating Temperature121.0??? ~ 135.0??? (Display Resolution; 0.1???)SterilantSaturated vaporAir Removal MethodPositive Pressure PulseAir Removal DeviceVacuum Pump (Diaphragm type)ControlsMicroprocessorDisplayDigital LED DisplayPanel Printer
(Optional)Exterior type, Direct thermal printing, Printing Paper Roll: W58 x ??60 mmPower SourceAC 230V, 50/60HzPower Consumption3,300 WNet Weight78 kgEnvironment Conditions
(IEC 61010-1)* Altitudes up to 2,000 m
* Temperature range of +5??? to +40???.
* Maximum Relative Humidity 80% for temperatures up to 31??? decreasing linearly to 50% relative humidity at 40???.
* Mains supply voltage fluctuations up to ??10% of the nominal.
* Installation Category (Overvoltage Category): ???, Pollution Degree : 2.
PLEASE NOTE: THIS UNIT REQUIRES A 15AMP POWER SUPPLY, PLEASE PHONE US TO DISCUSS AS ADDITIONAL CHARGES MAY APPLY
Product #:
HSA200
HSA215
Reservoir Tank for HS-2321BL
Hanshin S-Class Autoclave - Reservoir Tank for HS-2321BL
This S-Class large steam steriliser is equipped with a rectangular chamber, resulting in a more effective use of the volume of the chamber. The ability to process more kits concurrently saves time and allows improved clinic efficiency. In addition, the increased usable chamber size allows the processing of larger kits.
Overall Dimensions: W615 x D757 x H505 mmChamber Dimensions: W302 x D450 x H302 mm
1. Unique small steam generator This steriliser is equipped with the new type external steam generator which can vaporise water instantly, and the saturated vapor is injected into the chamber as a sterilising media, therefore the chamber is less contaminated than the internal steam generating type and the usable chamber space is widened because there is no heater assembly in the chamber. 2. Use of clean steam every cycleThe used water after completing a sterilising cycle is collected in the collecting container designed separately with the reservoir, therefore the saturated steam generated by a clean water always can be supplied to perform every sterilising cycle. 3. Safe and durable unwelded chamberBy adopting a integral chamber unwelded, the durability is excellent and a trouble such as leaking of pressurised vapor and vacuum during progressing a cycle is not occurred accidently. 4. Various cycle programs of the optimum condition5 kinds of the basic cycle program composed of the optimum sterilisation parameters are installed in this steriliser and the operator can select a proper cycle program among them conveniently for sterilising, moreover user can change the set values of the basic cycle programs as user's please if necessary for applying to a special sterilisation condition or materials. 5. Safe and convenient self-diagnosis functionIf an error has occurred during operating the steriliser, it is detected and the error code is displayed on the LED display accompanying an audible alarm, and the cycle in progress is aborted automatically for safety by the built-in self-diagnosis program.6. Convenient monitoring of a cycle processingThe operator is able to check a cycle progressing conveniently on the LED display because the state of steriliser operation is displayed digitally in real time on it. 7.Cycle Execution Data Storing and Ubiquitous FunctionThe cycle performance records executed at least for 11 years are stored in the control unit in order. The user can automatically search the results of sterilisation cycle performed previously by input the date performed cycle or the cycle count number and prints out the result record by the built-in panel printer. (optional specification) The user can download or backup those data in the USB memory and monitor the operation of steriliser on the external PC by connecting the USB or LAN cable to the built-in communication ports. Moreover the communication program including an ubiquitous function provided allows user to manage the operation of plural(maximum 15 sets) sterilisers at once. (optional specification)
* 2-year warranty.
ModelHS-3041SDOverall DimensionW615 x D757 x H505 ???ChamberW302 x D450 x H302 ???, Vol: 40.5???, Material: STS 316LMax. Working pressure: 2.4 bar / Min. Working Pressure: -1.00 bar
Max. Working Temperature: 138.0??? / Test Pressure : 5.13 barReservoir/Collection ContainerCapacity; 7.5??? / 7.5??? (Full water level)TrayW288 x D410 x H18 ???, 4 eaOperating Temperature121.0??? ~ 135.0??? (Display Resolution; 0.1???)SterilantSaturated vaporAir Removal MethodPositive Pressure PulseAir Removal DeviceVacuum Pump (Diaphragm type)ControlsMicroprocessorDisplayDigital LED DisplayPanel Printer
(Optional)Exterior type, Direct thermal printing, Printing Paper Roll: W58 x ??60 mmPower SourceAC 230V, 50/60HzPower Consumption3,300 WNet Weight78 kgEnvironment Conditions
(IEC 61010-1)* Altitudes up to 2,000 m
* Temperature range of +5??? to +40???.
* Maximum Relative Humidity 80% for temperatures up to 31??? decreasing linearly to 50% relative humidity at 40???.
* Mains supply voltage fluctuations up to ??10% of the nominal.
* Installation Category (Overvoltage Category): ???, Pollution Degree : 2.
PLEASE NOTE: THIS UNIT REQUIRES A 15AMP POWER SUPPLY, PLEASE PHONE US TO DISCUSS AS ADDITIONAL CHARGES MAY APPLY
Product #:
HSA215
HSA123
Door Gasket/Seal for HS-2522SD
Hanshin S-Class Autoclave - Door Gasket/Seal for HS-2522SD
This S-Class large steam steriliser is equipped with a rectangular chamber, resulting in a more effective use of the volume of the chamber. The ability to process more kits concurrently saves time and allows improved clinic efficiency. In addition, the increased usable chamber size allows the processing of larger kits.
Overall Dimensions: W615 x D757 x H505 mmChamber Dimensions: W302 x D450 x H302 mm
1. Unique small steam generator This steriliser is equipped with the new type external steam generator which can vaporise water instantly, and the saturated vapor is injected into the chamber as a sterilising media, therefore the chamber is less contaminated than the internal steam generating type and the usable chamber space is widened because there is no heater assembly in the chamber. 2. Use of clean steam every cycleThe used water after completing a sterilising cycle is collected in the collecting container designed separately with the reservoir, therefore the saturated steam generated by a clean water always can be supplied to perform every sterilising cycle. 3. Safe and durable unwelded chamberBy adopting a integral chamber unwelded, the durability is excellent and a trouble such as leaking of pressurised vapor and vacuum during progressing a cycle is not occurred accidently. 4. Various cycle programs of the optimum condition5 kinds of the basic cycle program composed of the optimum sterilisation parameters are installed in this steriliser and the operator can select a proper cycle program among them conveniently for sterilising, moreover user can change the set values of the basic cycle programs as user's please if necessary for applying to a special sterilisation condition or materials. 5. Safe and convenient self-diagnosis functionIf an error has occurred during operating the steriliser, it is detected and the error code is displayed on the LED display accompanying an audible alarm, and the cycle in progress is aborted automatically for safety by the built-in self-diagnosis program.6. Convenient monitoring of a cycle processingThe operator is able to check a cycle progressing conveniently on the LED display because the state of steriliser operation is displayed digitally in real time on it. 7.Cycle Execution Data Storing and Ubiquitous FunctionThe cycle performance records executed at least for 11 years are stored in the control unit in order. The user can automatically search the results of sterilisation cycle performed previously by input the date performed cycle or the cycle count number and prints out the result record by the built-in panel printer. (optional specification) The user can download or backup those data in the USB memory and monitor the operation of steriliser on the external PC by connecting the USB or LAN cable to the built-in communication ports. Moreover the communication program including an ubiquitous function provided allows user to manage the operation of plural(maximum 15 sets) sterilisers at once. (optional specification)
* 2-year warranty.
ModelHS-3041SDOverall DimensionW615 x D757 x H505 ???ChamberW302 x D450 x H302 ???, Vol: 40.5???, Material: STS 316LMax. Working pressure: 2.4 bar / Min. Working Pressure: -1.00 bar
Max. Working Temperature: 138.0??? / Test Pressure : 5.13 barReservoir/Collection ContainerCapacity; 7.5??? / 7.5??? (Full water level)TrayW288 x D410 x H18 ???, 4 eaOperating Temperature121.0??? ~ 135.0??? (Display Resolution; 0.1???)SterilantSaturated vaporAir Removal MethodPositive Pressure PulseAir Removal DeviceVacuum Pump (Diaphragm type)ControlsMicroprocessorDisplayDigital LED DisplayPanel Printer
(Optional)Exterior type, Direct thermal printing, Printing Paper Roll: W58 x ??60 mmPower SourceAC 230V, 50/60HzPower Consumption3,300 WNet Weight78 kgEnvironment Conditions
(IEC 61010-1)* Altitudes up to 2,000 m
* Temperature range of +5??? to +40???.
* Maximum Relative Humidity 80% for temperatures up to 31??? decreasing linearly to 50% relative humidity at 40???.
* Mains supply voltage fluctuations up to ??10% of the nominal.
* Installation Category (Overvoltage Category): ???, Pollution Degree : 2.
PLEASE NOTE: THIS UNIT REQUIRES A 15AMP POWER SUPPLY, PLEASE PHONE US TO DISCUSS AS ADDITIONAL CHARGES MAY APPLY
Product #:
HSA123
HSA213
Reservoir Tank for HS-3041SD
Hanshin S-Class Autoclave - Reservoir Tank for HS-3041SD
This S-Class large steam steriliser is equipped with a rectangular chamber, resulting in a more effective use of the volume of the chamber. The ability to process more kits concurrently saves time and allows improved clinic efficiency. In addition, the increased usable chamber size allows the processing of larger kits.
Overall Dimensions: W615 x D757 x H505 mmChamber Dimensions: W302 x D450 x H302 mm
1. Unique small steam generator This steriliser is equipped with the new type external steam generator which can vaporise water instantly, and the saturated vapor is injected into the chamber as a sterilising media, therefore the chamber is less contaminated than the internal steam generating type and the usable chamber space is widened because there is no heater assembly in the chamber. 2. Use of clean steam every cycleThe used water after completing a sterilising cycle is collected in the collecting container designed separately with the reservoir, therefore the saturated steam generated by a clean water always can be supplied to perform every sterilising cycle. 3. Safe and durable unwelded chamberBy adopting a integral chamber unwelded, the durability is excellent and a trouble such as leaking of pressurised vapor and vacuum during progressing a cycle is not occurred accidently. 4. Various cycle programs of the optimum condition5 kinds of the basic cycle program composed of the optimum sterilisation parameters are installed in this steriliser and the operator can select a proper cycle program among them conveniently for sterilising, moreover user can change the set values of the basic cycle programs as user's please if necessary for applying to a special sterilisation condition or materials. 5. Safe and convenient self-diagnosis functionIf an error has occurred during operating the steriliser, it is detected and the error code is displayed on the LED display accompanying an audible alarm, and the cycle in progress is aborted automatically for safety by the built-in self-diagnosis program.6. Convenient monitoring of a cycle processingThe operator is able to check a cycle progressing conveniently on the LED display because the state of steriliser operation is displayed digitally in real time on it. 7.Cycle Execution Data Storing and Ubiquitous FunctionThe cycle performance records executed at least for 11 years are stored in the control unit in order. The user can automatically search the results of sterilisation cycle performed previously by input the date performed cycle or the cycle count number and prints out the result record by the built-in panel printer. (optional specification) The user can download or backup those data in the USB memory and monitor the operation of steriliser on the external PC by connecting the USB or LAN cable to the built-in communication ports. Moreover the communication program including an ubiquitous function provided allows user to manage the operation of plural(maximum 15 sets) sterilisers at once. (optional specification)
* 2-year warranty.
ModelHS-3041SDOverall DimensionW615 x D757 x H505 ???ChamberW302 x D450 x H302 ???, Vol: 40.5???, Material: STS 316LMax. Working pressure: 2.4 bar / Min. Working Pressure: -1.00 bar
Max. Working Temperature: 138.0??? / Test Pressure : 5.13 barReservoir/Collection ContainerCapacity; 7.5??? / 7.5??? (Full water level)TrayW288 x D410 x H18 ???, 4 eaOperating Temperature121.0??? ~ 135.0??? (Display Resolution; 0.1???)SterilantSaturated vaporAir Removal MethodPositive Pressure PulseAir Removal DeviceVacuum Pump (Diaphragm type)ControlsMicroprocessorDisplayDigital LED DisplayPanel Printer
(Optional)Exterior type, Direct thermal printing, Printing Paper Roll: W58 x ??60 mmPower SourceAC 230V, 50/60HzPower Consumption3,300 WNet Weight78 kgEnvironment Conditions
(IEC 61010-1)* Altitudes up to 2,000 m
* Temperature range of +5??? to +40???.
* Maximum Relative Humidity 80% for temperatures up to 31??? decreasing linearly to 50% relative humidity at 40???.
* Mains supply voltage fluctuations up to ??10% of the nominal.
* Installation Category (Overvoltage Category): ???, Pollution Degree : 2.
PLEASE NOTE: THIS UNIT REQUIRES A 15AMP POWER SUPPLY, PLEASE PHONE US TO DISCUSS AS ADDITIONAL CHARGES MAY APPLY
Product #:
HSA213
HSA201
Printer Paper (10EA/Box)
Hanshin S-Class Autoclave - Printer Paper (10EA/Box)
This S-Class large steam steriliser is equipped with a rectangular chamber, resulting in a more effective use of the volume of the chamber. The ability to process more kits concurrently saves time and allows improved clinic efficiency. In addition, the increased usable chamber size allows the processing of larger kits.
Overall Dimensions: W615 x D757 x H505 mmChamber Dimensions: W302 x D450 x H302 mm
1. Unique small steam generator This steriliser is equipped with the new type external steam generator which can vaporise water instantly, and the saturated vapor is injected into the chamber as a sterilising media, therefore the chamber is less contaminated than the internal steam generating type and the usable chamber space is widened because there is no heater assembly in the chamber. 2. Use of clean steam every cycleThe used water after completing a sterilising cycle is collected in the collecting container designed separately with the reservoir, therefore the saturated steam generated by a clean water always can be supplied to perform every sterilising cycle. 3. Safe and durable unwelded chamberBy adopting a integral chamber unwelded, the durability is excellent and a trouble such as leaking of pressurised vapor and vacuum during progressing a cycle is not occurred accidently. 4. Various cycle programs of the optimum condition5 kinds of the basic cycle program composed of the optimum sterilisation parameters are installed in this steriliser and the operator can select a proper cycle program among them conveniently for sterilising, moreover user can change the set values of the basic cycle programs as user's please if necessary for applying to a special sterilisation condition or materials. 5. Safe and convenient self-diagnosis functionIf an error has occurred during operating the steriliser, it is detected and the error code is displayed on the LED display accompanying an audible alarm, and the cycle in progress is aborted automatically for safety by the built-in self-diagnosis program.6. Convenient monitoring of a cycle processingThe operator is able to check a cycle progressing conveniently on the LED display because the state of steriliser operation is displayed digitally in real time on it. 7.Cycle Execution Data Storing and Ubiquitous FunctionThe cycle performance records executed at least for 11 years are stored in the control unit in order. The user can automatically search the results of sterilisation cycle performed previously by input the date performed cycle or the cycle count number and prints out the result record by the built-in panel printer. (optional specification) The user can download or backup those data in the USB memory and monitor the operation of steriliser on the external PC by connecting the USB or LAN cable to the built-in communication ports. Moreover the communication program including an ubiquitous function provided allows user to manage the operation of plural(maximum 15 sets) sterilisers at once. (optional specification)
* 2-year warranty.
ModelHS-3041SDOverall DimensionW615 x D757 x H505 ???ChamberW302 x D450 x H302 ???, Vol: 40.5???, Material: STS 316LMax. Working pressure: 2.4 bar / Min. Working Pressure: -1.00 bar
Max. Working Temperature: 138.0??? / Test Pressure : 5.13 barReservoir/Collection ContainerCapacity; 7.5??? / 7.5??? (Full water level)TrayW288 x D410 x H18 ???, 4 eaOperating Temperature121.0??? ~ 135.0??? (Display Resolution; 0.1???)SterilantSaturated vaporAir Removal MethodPositive Pressure PulseAir Removal DeviceVacuum Pump (Diaphragm type)ControlsMicroprocessorDisplayDigital LED DisplayPanel Printer
(Optional)Exterior type, Direct thermal printing, Printing Paper Roll: W58 x ??60 mmPower SourceAC 230V, 50/60HzPower Consumption3,300 WNet Weight78 kgEnvironment Conditions
(IEC 61010-1)* Altitudes up to 2,000 m
* Temperature range of +5??? to +40???.
* Maximum Relative Humidity 80% for temperatures up to 31??? decreasing linearly to 50% relative humidity at 40???.
* Mains supply voltage fluctuations up to ??10% of the nominal.
* Installation Category (Overvoltage Category): ???, Pollution Degree : 2.
PLEASE NOTE: THIS UNIT REQUIRES A 15AMP POWER SUPPLY, PLEASE PHONE US TO DISCUSS AS ADDITIONAL CHARGES MAY APPLY
Product #:
HSA201
HSA202
Door Gasket Seal for HS-3041SD 11.5mm Thickness Rounded Edge
Hanshin S-Class Autoclave - Door Gasket Seal for HS-3041SD 11.5mm Thickness Rounded Edge
This S-Class large steam steriliser is equipped with a rectangular chamber, resulting in a more effective use of the volume of the chamber. The ability to process more kits concurrently saves time and allows improved clinic efficiency. In addition, the increased usable chamber size allows the processing of larger kits.
Overall Dimensions: W615 x D757 x H505 mmChamber Dimensions: W302 x D450 x H302 mm
1. Unique small steam generator This steriliser is equipped with the new type external steam generator which can vaporise water instantly, and the saturated vapor is injected into the chamber as a sterilising media, therefore the chamber is less contaminated than the internal steam generating type and the usable chamber space is widened because there is no heater assembly in the chamber. 2. Use of clean steam every cycleThe used water after completing a sterilising cycle is collected in the collecting container designed separately with the reservoir, therefore the saturated steam generated by a clean water always can be supplied to perform every sterilising cycle. 3. Safe and durable unwelded chamberBy adopting a integral chamber unwelded, the durability is excellent and a trouble such as leaking of pressurised vapor and vacuum during progressing a cycle is not occurred accidently. 4. Various cycle programs of the optimum condition5 kinds of the basic cycle program composed of the optimum sterilisation parameters are installed in this steriliser and the operator can select a proper cycle program among them conveniently for sterilising, moreover user can change the set values of the basic cycle programs as user's please if necessary for applying to a special sterilisation condition or materials. 5. Safe and convenient self-diagnosis functionIf an error has occurred during operating the steriliser, it is detected and the error code is displayed on the LED display accompanying an audible alarm, and the cycle in progress is aborted automatically for safety by the built-in self-diagnosis program.6. Convenient monitoring of a cycle processingThe operator is able to check a cycle progressing conveniently on the LED display because the state of steriliser operation is displayed digitally in real time on it. 7.Cycle Execution Data Storing and Ubiquitous FunctionThe cycle performance records executed at least for 11 years are stored in the control unit in order. The user can automatically search the results of sterilisation cycle performed previously by input the date performed cycle or the cycle count number and prints out the result record by the built-in panel printer. (optional specification) The user can download or backup those data in the USB memory and monitor the operation of steriliser on the external PC by connecting the USB or LAN cable to the built-in communication ports. Moreover the communication program including an ubiquitous function provided allows user to manage the operation of plural(maximum 15 sets) sterilisers at once. (optional specification)
* 2-year warranty.
ModelHS-3041SDOverall DimensionW615 x D757 x H505 ???ChamberW302 x D450 x H302 ???, Vol: 40.5???, Material: STS 316LMax. Working pressure: 2.4 bar / Min. Working Pressure: -1.00 bar
Max. Working Temperature: 138.0??? / Test Pressure : 5.13 barReservoir/Collection ContainerCapacity; 7.5??? / 7.5??? (Full water level)TrayW288 x D410 x H18 ???, 4 eaOperating Temperature121.0??? ~ 135.0??? (Display Resolution; 0.1???)SterilantSaturated vaporAir Removal MethodPositive Pressure PulseAir Removal DeviceVacuum Pump (Diaphragm type)ControlsMicroprocessorDisplayDigital LED DisplayPanel Printer
(Optional)Exterior type, Direct thermal printing, Printing Paper Roll: W58 x ??60 mmPower SourceAC 230V, 50/60HzPower Consumption3,300 WNet Weight78 kgEnvironment Conditions
(IEC 61010-1)* Altitudes up to 2,000 m
* Temperature range of +5??? to +40???.
* Maximum Relative Humidity 80% for temperatures up to 31??? decreasing linearly to 50% relative humidity at 40???.
* Mains supply voltage fluctuations up to ??10% of the nominal.
* Installation Category (Overvoltage Category): ???, Pollution Degree : 2.
PLEASE NOTE: THIS UNIT REQUIRES A 15AMP POWER SUPPLY, PLEASE PHONE US TO DISCUSS AS ADDITIONAL CHARGES MAY APPLY
Product #:
HSA202
HSA100
HS-3041SD - 40.5L with Printer
Hanshin S-Class Autoclave - HS-3041SD - 40.5L with Printer
This S-Class large steam steriliser is equipped with a rectangular chamber, resulting in a more effective use of the volume of the chamber. The ability to process more kits concurrently saves time and allows improved clinic efficiency. In addition, the increased usable chamber size allows the processing of larger kits.
Overall Dimensions: W615 x D757 x H505 mmChamber Dimensions: W302 x D450 x H302 mm
1. Unique small steam generator This steriliser is equipped with the new type external steam generator which can vaporise water instantly, and the saturated vapor is injected into the chamber as a sterilising media, therefore the chamber is less contaminated than the internal steam generating type and the usable chamber space is widened because there is no heater assembly in the chamber. 2. Use of clean steam every cycleThe used water after completing a sterilising cycle is collected in the collecting container designed separately with the reservoir, therefore the saturated steam generated by a clean water always can be supplied to perform every sterilising cycle. 3. Safe and durable unwelded chamberBy adopting a integral chamber unwelded, the durability is excellent and a trouble such as leaking of pressurised vapor and vacuum during progressing a cycle is not occurred accidently. 4. Various cycle programs of the optimum condition5 kinds of the basic cycle program composed of the optimum sterilisation parameters are installed in this steriliser and the operator can select a proper cycle program among them conveniently for sterilising, moreover user can change the set values of the basic cycle programs as user's please if necessary for applying to a special sterilisation condition or materials. 5. Safe and convenient self-diagnosis functionIf an error has occurred during operating the steriliser, it is detected and the error code is displayed on the LED display accompanying an audible alarm, and the cycle in progress is aborted automatically for safety by the built-in self-diagnosis program.6. Convenient monitoring of a cycle processingThe operator is able to check a cycle progressing conveniently on the LED display because the state of steriliser operation is displayed digitally in real time on it. 7.Cycle Execution Data Storing and Ubiquitous FunctionThe cycle performance records executed at least for 11 years are stored in the control unit in order. The user can automatically search the results of sterilisation cycle performed previously by input the date performed cycle or the cycle count number and prints out the result record by the built-in panel printer. (optional specification) The user can download or backup those data in the USB memory and monitor the operation of steriliser on the external PC by connecting the USB or LAN cable to the built-in communication ports. Moreover the communication program including an ubiquitous function provided allows user to manage the operation of plural(maximum 15 sets) sterilisers at once. (optional specification)
* 2-year warranty.
ModelHS-3041SDOverall DimensionW615 x D757 x H505 ???ChamberW302 x D450 x H302 ???, Vol: 40.5???, Material: STS 316LMax. Working pressure: 2.4 bar / Min. Working Pressure: -1.00 bar
Max. Working Temperature: 138.0??? / Test Pressure : 5.13 barReservoir/Collection ContainerCapacity; 7.5??? / 7.5??? (Full water level)TrayW288 x D410 x H18 ???, 4 eaOperating Temperature121.0??? ~ 135.0??? (Display Resolution; 0.1???)SterilantSaturated vaporAir Removal MethodPositive Pressure PulseAir Removal DeviceVacuum Pump (Diaphragm type)ControlsMicroprocessorDisplayDigital LED DisplayPanel Printer
(Optional)Exterior type, Direct thermal printing, Printing Paper Roll: W58 x ??60 mmPower SourceAC 230V, 50/60HzPower Consumption3,300 WNet Weight78 kgEnvironment Conditions
(IEC 61010-1)* Altitudes up to 2,000 m
* Temperature range of +5??? to +40???.
* Maximum Relative Humidity 80% for temperatures up to 31??? decreasing linearly to 50% relative humidity at 40???.
* Mains supply voltage fluctuations up to ??10% of the nominal.
* Installation Category (Overvoltage Category): ???, Pollution Degree : 2.
PLEASE NOTE: THIS UNIT REQUIRES A 15AMP POWER SUPPLY, PLEASE PHONE US TO DISCUSS AS ADDITIONAL CHARGES MAY APPLY
Product #:
HSA100
HSA211
Temperature Sensor (Chamber)
Hanshin S-Class Autoclave - Temperature Sensor (Chamber)
This S-Class large steam steriliser is equipped with a rectangular chamber, resulting in a more effective use of the volume of the chamber. The ability to process more kits concurrently saves time and allows improved clinic efficiency. In addition, the increased usable chamber size allows the processing of larger kits.
Overall Dimensions: W615 x D757 x H505 mmChamber Dimensions: W302 x D450 x H302 mm
1. Unique small steam generator This steriliser is equipped with the new type external steam generator which can vaporise water instantly, and the saturated vapor is injected into the chamber as a sterilising media, therefore the chamber is less contaminated than the internal steam generating type and the usable chamber space is widened because there is no heater assembly in the chamber. 2. Use of clean steam every cycleThe used water after completing a sterilising cycle is collected in the collecting container designed separately with the reservoir, therefore the saturated steam generated by a clean water always can be supplied to perform every sterilising cycle. 3. Safe and durable unwelded chamberBy adopting a integral chamber unwelded, the durability is excellent and a trouble such as leaking of pressurised vapor and vacuum during progressing a cycle is not occurred accidently. 4. Various cycle programs of the optimum condition5 kinds of the basic cycle program composed of the optimum sterilisation parameters are installed in this steriliser and the operator can select a proper cycle program among them conveniently for sterilising, moreover user can change the set values of the basic cycle programs as user's please if necessary for applying to a special sterilisation condition or materials. 5. Safe and convenient self-diagnosis functionIf an error has occurred during operating the steriliser, it is detected and the error code is displayed on the LED display accompanying an audible alarm, and the cycle in progress is aborted automatically for safety by the built-in self-diagnosis program.6. Convenient monitoring of a cycle processingThe operator is able to check a cycle progressing conveniently on the LED display because the state of steriliser operation is displayed digitally in real time on it. 7.Cycle Execution Data Storing and Ubiquitous FunctionThe cycle performance records executed at least for 11 years are stored in the control unit in order. The user can automatically search the results of sterilisation cycle performed previously by input the date performed cycle or the cycle count number and prints out the result record by the built-in panel printer. (optional specification) The user can download or backup those data in the USB memory and monitor the operation of steriliser on the external PC by connecting the USB or LAN cable to the built-in communication ports. Moreover the communication program including an ubiquitous function provided allows user to manage the operation of plural(maximum 15 sets) sterilisers at once. (optional specification)
* 2-year warranty.
ModelHS-3041SDOverall DimensionW615 x D757 x H505 ???ChamberW302 x D450 x H302 ???, Vol: 40.5???, Material: STS 316LMax. Working pressure: 2.4 bar / Min. Working Pressure: -1.00 bar
Max. Working Temperature: 138.0??? / Test Pressure : 5.13 barReservoir/Collection ContainerCapacity; 7.5??? / 7.5??? (Full water level)TrayW288 x D410 x H18 ???, 4 eaOperating Temperature121.0??? ~ 135.0??? (Display Resolution; 0.1???)SterilantSaturated vaporAir Removal MethodPositive Pressure PulseAir Removal DeviceVacuum Pump (Diaphragm type)ControlsMicroprocessorDisplayDigital LED DisplayPanel Printer
(Optional)Exterior type, Direct thermal printing, Printing Paper Roll: W58 x ??60 mmPower SourceAC 230V, 50/60HzPower Consumption3,300 WNet Weight78 kgEnvironment Conditions
(IEC 61010-1)* Altitudes up to 2,000 m
* Temperature range of +5??? to +40???.
* Maximum Relative Humidity 80% for temperatures up to 31??? decreasing linearly to 50% relative humidity at 40???.
* Mains supply voltage fluctuations up to ??10% of the nominal.
* Installation Category (Overvoltage Category): ???, Pollution Degree : 2.
PLEASE NOTE: THIS UNIT REQUIRES A 15AMP POWER SUPPLY, PLEASE PHONE US TO DISCUSS AS ADDITIONAL CHARGES MAY APPLY
Product #:
HSA211
HSA221
Door Gasket Seal for HS-3041SD 13mm Thickness Rectangular Edge
Hanshin S-Class Autoclave - Door Gasket Seal for HS-3041SD 13mm Thickness Rectangular Edge
This S-Class large steam steriliser is equipped with a rectangular chamber, resulting in a more effective use of the volume of the chamber. The ability to process more kits concurrently saves time and allows improved clinic efficiency. In addition, the increased usable chamber size allows the processing of larger kits.
Overall Dimensions: W615 x D757 x H505 mmChamber Dimensions: W302 x D450 x H302 mm
1. Unique small steam generator This steriliser is equipped with the new type external steam generator which can vaporise water instantly, and the saturated vapor is injected into the chamber as a sterilising media, therefore the chamber is less contaminated than the internal steam generating type and the usable chamber space is widened because there is no heater assembly in the chamber. 2. Use of clean steam every cycleThe used water after completing a sterilising cycle is collected in the collecting container designed separately with the reservoir, therefore the saturated steam generated by a clean water always can be supplied to perform every sterilising cycle. 3. Safe and durable unwelded chamberBy adopting a integral chamber unwelded, the durability is excellent and a trouble such as leaking of pressurised vapor and vacuum during progressing a cycle is not occurred accidently. 4. Various cycle programs of the optimum condition5 kinds of the basic cycle program composed of the optimum sterilisation parameters are installed in this steriliser and the operator can select a proper cycle program among them conveniently for sterilising, moreover user can change the set values of the basic cycle programs as user's please if necessary for applying to a special sterilisation condition or materials. 5. Safe and convenient self-diagnosis functionIf an error has occurred during operating the steriliser, it is detected and the error code is displayed on the LED display accompanying an audible alarm, and the cycle in progress is aborted automatically for safety by the built-in self-diagnosis program.6. Convenient monitoring of a cycle processingThe operator is able to check a cycle progressing conveniently on the LED display because the state of steriliser operation is displayed digitally in real time on it. 7.Cycle Execution Data Storing and Ubiquitous FunctionThe cycle performance records executed at least for 11 years are stored in the control unit in order. The user can automatically search the results of sterilisation cycle performed previously by input the date performed cycle or the cycle count number and prints out the result record by the built-in panel printer. (optional specification) The user can download or backup those data in the USB memory and monitor the operation of steriliser on the external PC by connecting the USB or LAN cable to the built-in communication ports. Moreover the communication program including an ubiquitous function provided allows user to manage the operation of plural(maximum 15 sets) sterilisers at once. (optional specification)
* 2-year warranty.
ModelHS-3041SDOverall DimensionW615 x D757 x H505 ???ChamberW302 x D450 x H302 ???, Vol: 40.5???, Material: STS 316LMax. Working pressure: 2.4 bar / Min. Working Pressure: -1.00 bar
Max. Working Temperature: 138.0??? / Test Pressure : 5.13 barReservoir/Collection ContainerCapacity; 7.5??? / 7.5??? (Full water level)TrayW288 x D410 x H18 ???, 4 eaOperating Temperature121.0??? ~ 135.0??? (Display Resolution; 0.1???)SterilantSaturated vaporAir Removal MethodPositive Pressure PulseAir Removal DeviceVacuum Pump (Diaphragm type)ControlsMicroprocessorDisplayDigital LED DisplayPanel Printer
(Optional)Exterior type, Direct thermal printing, Printing Paper Roll: W58 x ??60 mmPower SourceAC 230V, 50/60HzPower Consumption3,300 WNet Weight78 kgEnvironment Conditions
(IEC 61010-1)* Altitudes up to 2,000 m
* Temperature range of +5??? to +40???.
* Maximum Relative Humidity 80% for temperatures up to 31??? decreasing linearly to 50% relative humidity at 40???.
* Mains supply voltage fluctuations up to ??10% of the nominal.
* Installation Category (Overvoltage Category): ???, Pollution Degree : 2.
PLEASE NOTE: THIS UNIT REQUIRES A 15AMP POWER SUPPLY, PLEASE PHONE US TO DISCUSS AS ADDITIONAL CHARGES MAY APPLY
Product #:
HSA221