VOI Toggle Pin Orthopaedic
ORNXXX
Toggle pins are placed medial to the acetabular wall to anchor suture.
Toggle pins are placed medial to the acetabular wall to anchor suture.
Hip Toggle recommendations:
DiameterHip Hole DimensionToggle LengthSuture Size accepted2.7mm1.1mm10mmMetric 5 (#2)3.2mm1.1mm14mmMetric 5 (#2)4.0mm1.9mm18mmMetric 7 (#5)
We rcommend Knight Benedikt Ligasynth Suture for the hip toggle procedure. Depending on the size of suture used, the required acetabular wall drill bit may be approximately the same size as the toggle pin or up to 1-2 millimeters larger (to allow for large suture.). The diameter of the Actebaular hole must be large enough for the toggle pin and suture combination chosen. A 3.2mm toggle pin will require at minimum a 3.5mm hole. For the 4.0mm toggle pin, a 4.5mm or 5.5mm drill bit is recommended. The toggle pin-suture combination should be easily inserted through the acetabular drill hole. If difficulty is encountered, the acetabular hole may be enlarged with a larger drill bit.
We also recommend the following instruments to aid with the surgery:- IMEX Suture Passer
- IMEX Universal Aiming Device & Drill Guides or the VOI Aiming Guide C Frame
See also: Coxofemoral Luxation Starter Kit
I55032
3.2mm x 14mm
VOI Toggle Pin Orthopaedic - 3.2mm x 14mm
Toggle pins are placed medial to the acetabular wall to anchor suture.
Toggle pins are placed medial to the acetabular wall to anchor suture.
Hip Toggle recommendations:
DiameterHip Hole DimensionToggle LengthSuture Size accepted2.7mm1.1mm10mmMetric 5 (#2)3.2mm1.1mm14mmMetric 5 (#2)4.0mm1.9mm18mmMetric 7 (#5)
We rcommend Knight Benedikt Ligasynth Suture for the hip toggle procedure. Depending on the size of suture used, the required acetabular wall drill bit may be approximately the same size as the toggle pin or up to 1-2 millimeters larger (to allow for large suture.). The diameter of the Actebaular hole must be large enough for the toggle pin and suture combination chosen. A 3.2mm toggle pin will require at minimum a 3.5mm hole. For the 4.0mm toggle pin, a 4.5mm or 5.5mm drill bit is recommended. The toggle pin-suture combination should be easily inserted through the acetabular drill hole. If difficulty is encountered, the acetabular hole may be enlarged with a larger drill bit.
We also recommend the following instruments to aid with the surgery:- IMEX Suture Passer
- IMEX Universal Aiming Device & Drill Guides or the VOI Aiming Guide C Frame
See also: Coxofemoral Luxation Starter Kit
Product #:
I55032
I55040
4.0mm x 18mm
VOI Toggle Pin Orthopaedic - 4.0mm x 18mm
Toggle pins are placed medial to the acetabular wall to anchor suture.
Toggle pins are placed medial to the acetabular wall to anchor suture.
Hip Toggle recommendations:
DiameterHip Hole DimensionToggle LengthSuture Size accepted2.7mm1.1mm10mmMetric 5 (#2)3.2mm1.1mm14mmMetric 5 (#2)4.0mm1.9mm18mmMetric 7 (#5)
We rcommend Knight Benedikt Ligasynth Suture for the hip toggle procedure. Depending on the size of suture used, the required acetabular wall drill bit may be approximately the same size as the toggle pin or up to 1-2 millimeters larger (to allow for large suture.). The diameter of the Actebaular hole must be large enough for the toggle pin and suture combination chosen. A 3.2mm toggle pin will require at minimum a 3.5mm hole. For the 4.0mm toggle pin, a 4.5mm or 5.5mm drill bit is recommended. The toggle pin-suture combination should be easily inserted through the acetabular drill hole. If difficulty is encountered, the acetabular hole may be enlarged with a larger drill bit.
We also recommend the following instruments to aid with the surgery:- IMEX Suture Passer
- IMEX Universal Aiming Device & Drill Guides or the VOI Aiming Guide C Frame
See also: Coxofemoral Luxation Starter Kit
Product #:
I55040
I55027
2.7mm x 10.5mm
VOI Toggle Pin Orthopaedic - 2.7mm x 10.5mm
Toggle pins are placed medial to the acetabular wall to anchor suture.
Toggle pins are placed medial to the acetabular wall to anchor suture.
Hip Toggle recommendations:
DiameterHip Hole DimensionToggle LengthSuture Size accepted2.7mm1.1mm10mmMetric 5 (#2)3.2mm1.1mm14mmMetric 5 (#2)4.0mm1.9mm18mmMetric 7 (#5)
We rcommend Knight Benedikt Ligasynth Suture for the hip toggle procedure. Depending on the size of suture used, the required acetabular wall drill bit may be approximately the same size as the toggle pin or up to 1-2 millimeters larger (to allow for large suture.). The diameter of the Actebaular hole must be large enough for the toggle pin and suture combination chosen. A 3.2mm toggle pin will require at minimum a 3.5mm hole. For the 4.0mm toggle pin, a 4.5mm or 5.5mm drill bit is recommended. The toggle pin-suture combination should be easily inserted through the acetabular drill hole. If difficulty is encountered, the acetabular hole may be enlarged with a larger drill bit.
We also recommend the following instruments to aid with the surgery:- IMEX Suture Passer
- IMEX Universal Aiming Device & Drill Guides or the VOI Aiming Guide C Frame
See also: Coxofemoral Luxation Starter Kit
Product #:
I55027